telnet chronoskin 23node 2 of 490x40

chronoskin

Welcome back, caller

chronoskin is a board for people who keep old computers running. Three new messages are waiting in the boards you follow.

Last call: 5 October 2026, 21:14, from node 1. You have 42 minutes today.

  • 3on line
  • 41calls today
  • 12,480messages
  • 302files

main menu

boards

noboardtopicsmessageslast message
Hardware
1RepairsDead boards, leaking capacitors, tired power supplies.4125,106today 13:52
2Cables and adaptersPinouts, null modems, getting a picture on a new screen.1982,240today 09:30
3StorageFloppy drives, old hard disks and what replaces them.1671,9354 Oct
Software
4Operating systemsInstalling, booting and patching systems nobody ships any more.2202,387yesterday
5Terminal programsSettings, transfer protocols and character sets.6481228 Sep

new for you

from the sysop

The board is down on Sunday from 02:00 to 04:00 while the disk is copied to a new machine.

disk copy######....60%

Node 4The fourth of the four lines into the board. now answers at 14400. Tell me if it drops you.

  1. main menu
  2. >
  3. boards
  4. >
  5. Cables and adapters

Cables and adapters

Board 2. 198 topics, 2,240 messages, 2 new for you.

mine

You have not written in this board yet.

start a topic
  1. main menu
  2. >
  3. Cables and adapters
  4. >
  5. topic 198

Null modem for a 9-pin port

7 messages since 2 October. Messages 1 and 7 are shown.

Pinned: the sysop keeps the first message of this topic up to date.

Line noise: message 5 arrived damaged and was left out. Its writer has been asked to send it again.

message 1 of 7

From:
mi mira regular
Date:
2 October 2026, 20:41

A null modem in seven wires

Two machines that both think they are the terminal need their lines crossed. For a 9-pin port on each side this is the full cable; it works with every program I have tried.

What crosses

  • 2 to 3 and 3 to 2: data.
  • 7 to 8 and 8 to 7: the two ask and answer lines.
  • 4 to 6 and 6 to 4, with 5 straight through as ground.

The short version

With flow control switched off, pins 2, 3 and 5 are enough. Set 9600 8N1 on both ends first.

-- mira, still soldering

reply quote next

Write a message

To a board, or to the sysop alone. Plain text, 72 columns.

error: a message needs a subject.

A line that starts with > is shown as a quote.

house rules

Say which machine. Quote two lines, not twenty. Files go in the file area, not in a message.

How long may a message be?

As long as it needs, in lines of 72 columns.

Where do files go?

In the file area. A message only names them.