chronoskin Repairs, restorations and bench talk since 2002

Welcome to the chronoskin boards.

If this is your first visit, read the help pages first. You need an account before you can post; reading is open to everyone. Pick a board below to start.

Read the board rules

Members: 4,812, Topics: 21,340, Posts: 187,455 The time now is 09:41 PM. You last visited: 14 Mar 2005, 07:02 PM.

The boards will be read-only on Sunday from 02:00 to 04:00 while the server is moved. Read the announcement.

Board Topics Posts Last post
The workbench
Radios and receivers Fault finding, alignment and restoration of domestic sets. Moderators: hollis_w, m.teague 5,208 48,917 Today, 09:12 PM by quietfuse
Test equipment Meters, scopes, signal generators and bench supplies. Please give the model number in the topic title. Moderator: m.teague 2,744 19,630 Today, 08:47 PM by anselm
Clocks and movements Mechanical and synchronous clocks, timers and chart drives. Moderator: pendle 913 7,052 13 Mar 2005, 11:20 AM by ruth_a
The back room
Introductions New here? Say hello and tell us what is on your bench. 1,387 9,441 12 Mar 2005, 06:35 PM by dovecote
Archive 2002 to 2003 Read-only topics from the old board. 6,119 52,870 30 Dec 2003, 10:02 PM by hollis_w
Mark all boards read · The moderating team
  • New posts
  • No new posts
  • Locked board
All times are GMT.

Board statistics

4,812Members
21,340Topics
187,455Posts
58Online now
412Most ever online

Who is online

Currently active: 58 (21 members and 37 guests)

Most users ever online was 412, on 02 Nov 2004 at 08:31 PM.

anselm, dovecote, hollis_w, ivo_k, m.teague, pendle, quietfuse, ruth_a, saltmarsh, tobias_k

Our members have made 187,455 posts in 21,340 topics. Welcome to our newest member, saltmarsh.

  1. chronoskin
  2. The workbench
  3. Test equipment

Test equipment

Meters, scopes, signal generators and bench supplies. Moderator: m.teague

Sub-boards of Test equipment

Meters and bridges 412 topics, 3,906 posts Last post today, 07:55 PM
Oscilloscopes 688 topics, 5,120 posts Last post today, 06:10 PM
Signal generators 203 topics, 1,477 posts Last post 12 Mar 2005
Bench supplies 1,950 topics, 8,233 posts Last post 11 Mar 2005
Topic Replies Views Last post
Bench supply hums at low load New Started by quietfuse 31 1,204 Today, 08:47 PM by anselm
Calibrating a moving-coil meter without a standard Solved Started by ivo_k 18 942 Today, 05:30 PM by m.teague
Signal generator drifts for the first hour Awaiting parts Started by tobias_k 7 265 13 Mar 2005, 09:14 PM by tobias_k
Mains isolation: read before you ask Locked Started by m.teague 0 6,318 02 Jan 2005, 10:00 AM by m.teague
Replacement probes for an old valve voltmeter Started by saltmarsh 4 187 11 Mar 2005, 02:41 PM by dovecote
Mark this board read · Subscribe to this board
  • New posts
  • No new posts
  • Locked topic
137 topics in this board.
  1. chronoskin
  2. Test equipment
  3. Bench supply hums at low load

Bench supply hums at low load

Started by quietfuse on 14 Mar 2005. 31 replies, 1,204 views. New

14 Mar 2005, 06:02 PMPost 1 of 32

I have a twin 0 to 30 V bench supply from the early seventies on the bench. Above about half an amp it is quiet. Below that the transformer hums loudly enough to hear across the room, and there is 40 mV of ripple on the output.

Rectifier diodes test fine. The reservoir capacitor is original and reads 3,900 uF against a marked 4,700. Is that enough to explain it, or should I be looking at the regulator?

One fault at a time.

Profile · Send a private message Quote · Edit · Delete · Report
14 Mar 2005, 06:40 PMPost 2 of 32
quietfuse wrote: The reservoir capacitor is original and reads 3,900 uF against a marked 4,700.

Capacitance is only half of it. Measure the series resistance as well; a thirty year old electrolytic can read nearly full value and still be useless. I would replace it before touching anything else.

Hum that gets worse at light load usually points at the regulator hunting, not the transformer. Check the small compensation capacitor across the error amplifier while you are in there.

Put the model number in the title, please.

Profile · Send a private message Quote · Edit · Delete · Report
Today, 08:47 PMPost 32 of 32

Same supply here, same fault. On mine it was the minimum load resistor across the output, which had gone open. Without it the series pass transistor cannot regulate down at low current and the loop sings at mains frequency.

It is a 2 W wirewound part under the rear terminal strip. Discharge the reservoir before you reach in.

Profile · Send a private message Quote · Edit · Delete · Report
  1. chronoskin
  2. Test equipment
  3. Bench supply hums at low load
  4. Post a reply

Post a reply

In the topic Bench supply hums at low load. Posting as quietfuse.

Post a reply

This is not a complete e-mail address.
Options
Cancel
  • Topic review, newest first
  • anselm On mine it was the minimum load resistor across the output, which had gone open.
    Today, 08:47 PM Post 32
  • tobias_k Worth checking the mains earth bond to the chassis too; mine was loose under the paint.
    Today, 07:15 PM Post 31
  • m.teague Hum that gets worse at light load usually points at the regulator hunting, not the transformer.
    14 Mar 2005, 06:40 PM Post 2
  1. chronoskin
  2. Control panel

Control panel

Signed in as quietfuse. Member since August 2003. Last visit: 14 Mar 2005, 07:02 PM.

Your activity

412Posts
37Topics started
3Subscriptions
0Unread messages
Subscribed topic Replies Last post
Bench supply hums at low load New In Test equipment 31 Today, 08:47 PM by anselm
Which lacquer for a walnut cabinet? Sticky In Cabinets and finishes 62 13 Mar 2005, 04:18 PM by pendle
Calibrating a moving-coil meter without a standard Solved In Test equipment 18 Today, 05:30 PM by m.teague

Private messages: inbox

Your inbox is empty. Messages from other members will be listed here.

Write a message
  1. chronoskin
  2. Help
  3. Board rules

Help and rules

How the boards work and what the moderating team expects. Last revised 02 Jan 2005.

Board rules and posting guide

Everyone who posts here agrees to the rules below. They are short. Read them once and you will rarely need a moderator.

Before you post

Search first; most common faults have a long topic already. Put the make and model in the title, and say what you have measured so far. A good first post saves three replies asking for the basics.

  • One topic per fault, in one board only.
  • Attach schematics as links, not as inline scans.
  • Mains work: say whether the set is isolated before you ask for measurements.
  • Wrap part numbers in [code] tags so they stay readable.

Signatures

Signatures are limited to three lines of text and no images. Set yours in the control panel.

Moderation

Moderators may edit a title to add a model number, move a topic to the right board, or lock one that has run its course. Disagree by private message, not in the topic.

See also